Portable Cord & Power Cable

Copper Conductor

Internal Wiring, Power Cable

EPR Insulation, PVC Jacket, Non-shielded, 5kV – Copper

Used, typically, for OEM equipment such as switchgear, transformers, etc. Intended solely for use as factory-installed wiring equipment (internal wiring), in industrial applications where such cable systems are maintained by trained personnel, not as type MV. These cables must be protected and are not to be in contact by personnel while energized.

Internal Wiring, Power Cable

XLPE Insulation, Non-shielded, 5kV – Copper

Used, typically, for OEM equipment such as switchgear, transformers, etc. Intended solely for use as factory-installed wiring equipment (internal wiring), in industrial applications where such cable systems are maintained by trained personnel, not as type MV. These cables must be protected and are not to be in contact by personnel while energized.

Type W

EPR Insulation, CPE Jacket, 2kV – Tinned Coated Copper

Type W is a portable or fixed power cable used in mining and industrial applications where high reliability is required. For use in wet or dry locations, installed in conduits, ducts or trays and sunlight exposed.

Type W 2C-4C

EPR Insulation, CPE Jacket, 2kV – Tinned Coated Copper

Trailing cable on ac mining equipment where a ground check conductor is not required for fail-safe ground monitoring. For use where arc suppressors or diodes are utilized for grounding monitoring, or induced voltages do not present a problem.

Type G-GC 3C

EPR Insulation, CPE Jacket, 2kV – Tinned Coated Copper

Trailing cable on ac mining equipment where a ground conductor is required. For use where induced voltages in grounding system will not produce a hazard.

Type SHD-GC 3C

EPR Insulation, CPE Jacket, Composite Fiber Copper Braid Shielded, 2kV – Tinned Coated Copper

For use with Bretby type cable handling devices on longwall machines and as trailing cable on ac mining equipment where a ground check conductor is required for fail-safe ground monitoring. For use where induce voltages in grounding system will not produce a hazard. This cable is designed for use on low and medium voltage AC circuits where shielding is desired or required.

Type SHD-GC 3C

EPR Insulation, CPE Jacket, Composite Fiber Copper Braid Shielded, 100% I.L., 5kV-25kV – Tinned Coated Copper

Trailing cable on ac mining equipment where service conditions are severe and maximum safety is mandatory; such as power shovels and drag lines in open-pit mines, quarries, gantry cranes and slag reclaiming.

Type MP-GC Mining Cable

XLPE Insulation, PVC Jacket, Copper Tape Shielded, 100% & 133% I.L., 5kV-25kV – Copper

High voltage distribution intended for permanent installations. Suitable for underground mining and boreholes. Can be used in aerial installations, ducts or direct burial.

Type MP-GC Mining Cable

EPR Insulation, CPE Jacket, Copper Tape Shielded, 100% & 133% I.L., 5kV-25kV – Copper

High voltage distribution intended for permanent installations. Suitable for underground mining and boreholes. Can be used in aerial installations, ducts or direct burial.

Diesel Locomotive Cable (DLO)

EPR Insulation, CPE Jacket, 2kV – Tinned Coated Copper

As power cable used in DLO locomotive cabel in diesel locomotive cable, railroad and transit car wiring where high reliability is required. Also suitable for use in static and dynamic wind power applications. For portable and fixed installations leads for motors, generators, and batteries.

Diesel Locomotive Cable (DLO)

EPR Insulation, CPE Jacket, 600V, 1kV & 2kV – Copper

Suitable for use in static and dynamic wind power applications. For portable and fixed installations leads for motors, generators, and batteries. Also as power cable used as DLO locomotive cable in railroad and transit car wiring.

Type SOOW Flexible Cord

EPR Insulation, CPE Jacket, 600V – Copper

Portable cord for electrical power supply and general use in equipment exposed to severe environments. For use outdoors in wet or dry locations.

Type SOW Flexible Cord

EPR Insulation, CPE Jacket, 600V – Copper

Portable cord for electrical power supply and general use in equipment exposed to severe environments. For use outdoors in wet or dry locations.

Type STOW Flexible Cord

PVC Insulation, PVC Jacket, 600V – Copper

Portable cord for electrical power supply and general use in equipment exposed to severe environments. For use outdoors in wet or dry locations, pendants, connection of portable lamps, portable and mobile signs or appliances, wiring of cranes or hoists, and as permitted by NEC, Article 400.7.

Traction Cable

EPR Insulation, XLPO Jacket, LSOH Jacket, 2kV – Copper

Used for underground installation in non-metallic, concrete encased duct bank or pendant trapeze struts and supported by insulating clamps in substations. Suitable for use in wet and dry locations, and to operate continuously at rated value temperature range of -40° to 90°C.

Type P Drilling Rig & Marine Cable

Power/Distribution Cable, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 2000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used for the distribution of power in circuits rated for 2000 volts. Typical applications include DC motor cables, generators, transformers, top drives, and other applications that may require a highly flexible rugged power cable.

Type P Drilling Rig & Marine Cable

Power/Distribution Cable, Single Conductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used for the distribution of power in circuits rated for 600 and 1000 volts. Typical applications include DC motor cables, generators, transformers, top drives, and other applications that may require a highly flexible rugged power cable.

Type P Drilling Rig & Marine Cable

Power/Distribution Cable, Multiconductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used for the distribution of power in circuits rated for 600 and 1000 volts or may be used in lighting, communication, and control. Typical applications include AC motor power, distribution panel feeders, transformer feeders, lighting panels, light fixtures, plugs/receptacles, and remote motor controls.

Type P VFD Power Cable, Drilling Rig & Marine Cable

Three (3) Conductors, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 2000V – Tinned Coated Copper

Used in variable frequency AC motor driver (VFD) applications. Flexible conductors for easy handling and installation, with an overall composite shield formed by a copper wire braid and an aluminum foil shield providing 100% coverage to contain the VFD EMI emissions, and with grounding conductors distributed symmetrical to reduce induced voltage imbalances and carry common mode noise back to the drive.

Type T/N Drilling Rig & Marine Cable

Power/Distribution Cable, Single Conductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used for the distribution of power in circuits or may be used in lighting, communication, and control in circuits rated for 600 or 1000 volts.

Type T/N Drilling Rig & Marine Cable

Power/Distribution Cable, Multiconductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used for the distribution of power in circuits or may be used in lighting, communication, and control in circuits rated for 600 or 1000 volts.

Type LS Drilling Rig & Marine Cable

Power/Distribution Cable, Single Conductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Used for the distribution of power in circuits rated for 600/1000 volts. Typical applications include D/C motor cables, generators, transformers, top drives, and other applications that may require a highly flexible rugged power cable.

Type LS Drilling Rig & Marine Cable

Power/Distribution Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Used for the distribution of power in circuits rated for 600/1000 volts or may be used in lighting, communication, and control. Typical applications include A/C motor power, distribution pane feeders, transformer feeders, lighting panels, light fixtures, plugs/receptacles, and remote controls.

TC-THHN/THWN-2

PVC Insulation & Nylon Cover, PVC Jacket, VW-1, SR, ER, FT4, Dir. Bur., 600V – Copper

Specifically approved for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations. For use in accordance with NEC®, Article 336, in cable trays, in raceways, or where supported in outdoor locations supported by a messenger wire.

Type MC

THHN/THWN-2, Singles, PVC Insulation & Nylon Cover, Green Insulated Ground, 600V – Copper

For services, feeders, and branch circuits. For power, lighting, control and signal circuits. Exposed or concealed. In cable tray and approved raceway. In dry locations and embedded in plaster finish on brick or other mansonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div 2, and Class III Div hazardous locations, in accordance with NEC®.

Type MC

THHN/THWN-2, Singles, PVC Insulation & Nylon Cover, Green Insulated Ground & Additional Isolated Ground, 600V – Copper

Where a redundant or isolated grounding paths are required. For services, feeders, and branch circuits. For power, lighting, control and signal circuits. Exposed or concealed. In cable tray and approved raceway. In dry locations and embedded in plaster finish on brick or other mansonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div. 2, and Class III Div. 1 hazardous locations, in accordance with NEC®.

Type MC-HCF-AIA, Aluminum Bonding Wire in Contact with Armor

PVC Insulation & Nylon Cover, Green Armor, 600V – Copper

For installations requiring redundant, dedicated or isolated grounding paths. Used in health care facilities for branch circuit wiring in patient care areas of hospitals, medical centers, nursing homes, dental offices, clinics, outpatient facilites and other health care facilities in accordance with NEC® Articles 517, 330 and 300.4 as applicable. (Note: Use in hazardous anesthetizing areas is not permitted.) For places of assemblies and theaters per NEC® Articles 518 and 520, respectively. In cable tray and approved raceways. In dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div. 2, and Class III Div. 1 hazardous locations, in accordance with NEC®. Requires use of UL Listed MCI-A fittings.

Type MC-PCS-AIA, Jacketed Pair Signal Cable under AIA Armor

PVC Insulation & Nylon Cover, 600V – Copper

For services, feeders, and branch circuits. Suitable for power, lighting, control, and signal circuits requiring the use of signal cable in multi-residential, commercial, institutional and industrial applications. Ideal for luminary or LED controls and for SMART buildings. Exposed or concealed. In cable tray an approved raceway. In dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div. 2, and Class III Div. 1 hazardous locations, in accordance with NEC®.

Aluminum Conductor

Internal Wiring, Power Cable

XLPE Insulation, Non-shielded, 5kV – Aluminum

Used, typically, for OEM equipment such as switchgear, transformers, etc. Intended solely for use as factory-installed wiring equipment (internal wiring), in industrial applications where such cable systems are maintained by trained personnel, not as type MV. These cables must be protected and are not to be in contact by personnel while energized.

Internal Wiring, Power Cable

XLPE Insulation, Non-shielded, 5kV – Aluminum

Used, typically, for OEM equipment such as switchgear, transformers, etc. Intended solely for use as factory-installed wiring equipment (internal wiring), in industrial applications where such cable systems are maintained by trained personnel, not as type MV. These cables must be protected and are not to be in contact by personnel while energized.