Tray & Control Cable

Copper Conductor

TC-TFN/TFFN

PVC Insulation & Nylon Cover, PVC Jacket, 600V – Copper

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.

TC-THHN/THWN-2

PVC Insulation & Nylon Cover, PVC Jacket, SR, GR, 600V – Copper

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.

TC-THHN/THWN-2

PVC Insulation & Nylon Cover, PVC Jacket, VW-1, SR, ER, FT4, Direct Burial, 600V – Copper

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.

TC-THHN/THWN-2

PVC Insulation & Nylon Cover, PVC Jacket, ER, FT4, RoH, 600V – Copper

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.

TC-XHHW-2

XLPE Insulation, PVC Jacket, ER, SR, PR, Direct Burial, 600V – Copper

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.

TC-XHHW-2

XLPE Insulation, PVC Jacket, ER, FT4, RoHS, Direct Burial, Singles, VW-1, GR I & II, SR, RW90, RoHS, 600V – Copper

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.

TC-RHH/RHW-2/USE-2

XLPE Insulation, PVC Jacket, ER, 600V – Copper

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.

TC-Control Cable

20/10 PE Insulation & PVC Cover, PVC Jacket, 600V – Copper

Control cable circuits for utilities systems, industrial plants and for general purpose or applications. Suitable for the operation and interconnection of protective devices. May be used in open air, in ducts and conduit, wet and dry locations.

Type P Drilling Rig & Marine Cable

Control Cable, Multiconductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600V & 1kV – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include driller’s console, fire and gas detection systems, bilge and ballast controls, and general alarm systems.

Type P Pairs, Individual Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type P Pairs, Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type P Pairs, Individual & Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconducter, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type P Triads, Individual Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type P Triads, Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type P Triads, Individual & Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, XLPO Insulation, Heavy Duty Arctic Type CPE Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities where harsh marine environments exist. Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type T/N Drilling Rig & Marine Cable

Power/Distribution Cable, Single Conductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used for the distribution of power in circuits or may be used in lighting, communication, and control in circuits rated for 600 or 1000 volts.

Type T/N Drilling Rig & Marine Cable

Power/Distribution Cable, Multiconductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used for the distribution of power in circuits or may be used in lighting, communication, and control in circuits rated for 600 or 1000 volts.

Type T/N Drilling Rig & Marine Cable

Control Cable, Multiconductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used in control, indicating, communication, electronic, and similar circuits where multiple conducter cables are required.

Type T/N Pairs, Individual Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Specifically designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used for signal transmission where twisted groups of conductors are desired. Individual or overall group shielding is provided to prevent electrostatic and/or electromagnetic in reference in circuits rated for 300 volts.

Type T/N Pairs, Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Specifically designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used for signal transmission where twisted groups of conductors are desired. Individual or overal group shielding is provided to prevent electrostatic and/or electromagnetic inerference in circuits rated for 300 volts.

Type T/N Pairs, Individual & Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, PVC Insulation & Nylon Cover, PVC Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Copper

Specifically designed for the installation and use in marine environments on offshore drilling rigs, aboard marine vessels, and on fixed and floating offshore facilities. Used for signal transmission where twisted groups of conductors are desired. Individual or overal group shielding is provided to prevent electrostatic and/or electromagnetic inerference in circuits rated for 300 volts.

Type LS Drilling Rig & Marine Cable

Power/Distribution Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Used for the distribution of power in circuits rated for 600/1000 volts or may be used in lighting, communication, and control. Typical applications include A/C motor power, distribution pane feeders, transformer feeders, lighting panels, light fixtures, plugs/receptacles, and remote controls.

Type LS Drilling Rig & Marine Cable

Control Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 600/1000V – Tinned Coated Copper

Used in control, indicating, communication, electronic, and similar circuits where multiple conductor cables are required. Typical applications include driller’s console, fire and gas detection systems, video camera systems, bilge and ballast controls, and general alarm systems.

Type LS Pairs, Individual Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 150/250V – Tinned Coated Copper

Used in signal transmission application where twisted groups of conductors are desired, also with overall or individual shielding to prevent electrostatic and/or electromagnetic interference. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type LS Pairs, Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 150/250V – Tinned Coated Copper

Used in signal transmission application where twisted groups of conductors are desired, also with overall or individual shielding to prevent electrostatic and/or electromagnetic interference. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type LS Pairs, Individual & Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 150/250V – Tinned Coated Copper

Used in signal transmission application where twisted groups of conductors are desired, also with overall or individual shielding to prevent electrostatic and/or electromagnetic interference. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type LS Triads, Individual Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 150/250V – Tinned Coated Copper

Used in signal transmission application where twisted groups of conductors are desired, also with overall or individual shielding to prevent electrostatic and/or electromagnetic interference. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type LS Triads, Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 150/250V – Tinned Coated Copper

Used in signal transmission application where twisted groups of conductors are desired, also with overall or individual shielding to prevent electrostatic and/or electromagnetic interference. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

Type LS Triads, Individual & Overall Shield, Drilling Rig & Marine Cable

Signal & Instrumentation Cable, Multiconductor, HF XLPE Insulation, SHF1 Jacket, Armored or Unarmored, or Armored & Sheathed, 150/250V – Tinned Coated Copper

Used in signal transmission application where twisted groups of conductors are desired, also with overall or individual shielding to prevent electrostatic and/or electromagnetic interference. Typical applications include tank level indicators, fire and gas protection systems, communication systems, CO₂ systems, and smoke detector systems.

TC-THHN/THWN-2

PVC Insulation & Nylon Cover, PVC Jacket, VW-1, SR, ER, FT4, Dir. Bur., 600V – Copper

Specifically approved for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations. For use in accordance with NEC®, Article 336, in cable trays, in raceways, or where supported in outdoor locations supported by a messenger wire.

Type MC

THHN/THWN-2, Singles, PVC Insulation & Nylon Cover, Green Insulated Ground, 600V – Copper

For services, feeders, and branch circuits. For power, lighting, control and signal circuits. Exposed or concealed. In cable tray and approved raceway. In dry locations and embedded in plaster finish on brick or other mansonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div 2, and Class III Div hazardous locations, in accordance with NEC®.

Type MC

THHN/THWN-2, Singles, PVC Insulation & Nylon Cover, Green Insulated Ground & Additional Isolated Ground, 600V – Copper

Where a redundant or isolated grounding paths are required. For services, feeders, and branch circuits. For power, lighting, control and signal circuits. Exposed or concealed. In cable tray and approved raceway. In dry locations and embedded in plaster finish on brick or other mansonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div. 2, and Class III Div. 1 hazardous locations, in accordance with NEC®.

Type MC-HCF-AIA, Aluminum Bonding Wire in Contact with Armor

PVC Insulation & Nylon Cover, Green Armor, 600V – Copper

For installations requiring redundant, dedicated or isolated grounding paths. Used in health care facilities for branch circuit wiring in patient care areas of hospitals, medical centers, nursing homes, dental offices, clinics, outpatient facilites and other health care facilities in accordance with NEC® Articles 517, 330 and 300.4 as applicable. (Note: Use in hazardous anesthetizing areas is not permitted.) For places of assemblies and theaters per NEC® Articles 518 and 520, respectively. In cable tray and approved raceways. In dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div. 2, and Class III Div. 1 hazardous locations, in accordance with NEC®. Requires use of UL Listed MCI-A fittings.

Type MC-PCS-AIA, Jacketed Pair Signal Cable under AIA Armor

PVC Insulation & Nylon Cover, 600V – Copper

For services, feeders, and branch circuits. Suitable for power, lighting, control, and signal circuits requiring the use of signal cable in multi-residential, commercial, institutional and industrial applications. Ideal for luminary or LED controls and for SMART buildings. Exposed or concealed. In cable tray an approved raceway. In dry locations and embedded in plaster finish on brick or other masonry except in damp or wet locations. Per NEC® 300.22 (C), in environmental air-handling spaces. Class I Div. 2, Class II Div. 2, and Class III Div. 1 hazardous locations, in accordance with NEC®.

Aluminum Conductor

TC-XHHW-2

XLPE Insulation, PVC Jacket, ER, SR, PR, Direct Burial, AA-8000, 600V, Aluminum

Used for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations.